OP-FSM-02
Description
The OP-FSM is an ideal solution for measuring, comparing and starting up an induction loop system according to the requierements of the IEC 60118-4 Norm.
The ergonomically designed, handheld meter has two calibrated measuring functions and two filter settings for the evaluation of background noise and the magnetic field strength. You can use the OP-FSM with headphone to listen to and test the loop signal.
The OP-778 is an adjustable and equipped with shape memory earmuffs, it allows a better listening comfort. It is light and foldable for more mobility and space saving storage.
Characteristics
| OP-FSM | |
| SCALE CALIBRATION | |
| Operating mode -20dB | -20dB = 0,043 A/m |
| Operating mode 0dB | 0dB = 0,4 A/m |
| Type of measurement | True RMS 125 ms |
| FREQUENCY RESPONSE | |
| Filter | A/FLAT |
| 30Hz…500Hz | -3dB…-4dB |
| 500Hz…2500Hz | +/- 0,25 dB |
| 2500HZ…10kHz | +/-3 dB |
| OUTPUTS | |
| Display | Color-coded LED dot display |
| Headphones | 3,5mm cinch |
| POWER SUPPLY | |
| Batteries | 2x AA |
| Indicator lights | LED |
| Service life | 100h |
| DIMENSIONS | |
| Dimensions (W x H x D) | 83 x 126 x 35 mm |
| Poids | Approx. 300g |